Starters: 2 Different Types of Starters to Start Squirrel Cage Electric Motor

Different types of starters are used to start the different types of electric motors.

As you know, electric motors are used to drive air compressors.

These electric motors are of different types as per the requirement of the customer.

As different electric motors are used, different type of starters is required to start these motors.

Particular types of starters are required for a particular type of motor.

An electrical engineer concerned might better know about the starters.

But to understand the basics of starters, I have shared information in a simple format.

  • Star-Delta Starters

These are used where starting current limitations do not permit the use of DOL Starter.

In Star-delta starting, the motor is started in the “Star” connection.

The connection is changed over to “Delta” when the motor has reached nearly 80% of the rated speed, and starting current dropped to the lowest.

By connecting the motor in “Star” during the starting period, the impressed phase voltage is reduced58% of the voltage in the “Delta” connection.

The corresponding current in “Star” is thus only one third that in “Delta”.

By starting in “Star” the current is reduced to only about 2 to 2.5 times the rated current.

The motor is started in “Star” and once it has peaked up speed, its connections are changed over to “Delta”, by means of a timer in an automatic type starter and by manual in manually operated starters.

This time varies from 6 seconds to 12 seconds or more according to the load factor.

Manually operated starters are oil-immersed types, where the fixed and moving contacts are totally immersed.

  • Direct On Line Starters

Normally this starter is of the automatic type, simple, consisting of only one main contractor.

Its starting current is 6 to 7.5 times the motor rated current.

In view of the very high starting current, large capacity DOL starters are in High Voltage (HV) grade.

In the case where the direct starting method cannot be employed because of the high initial peak current, the Squirrel Cage Motor has to be started on reduced voltage i.e. Star-Delta starting method.

Besides this information, you are suggested to read something more from below engineering books

So, Here you find the Best Engineering Resources for further details

To get the more details about the topic, I further recommended reading

If you like the post, share it with your friends and also on social sites.

Recent Posts

Energy Conservation: 11 Proven Ways to a Better Energy Conservation

Energy conservation may be the best solution to fight the energy problems we are facing today. It will also help…

Geothermal Energy: 7 Things You Must Know About Earth’s Heat Energy

In engineering, geothermal energy definition is “The heat energy generated and stored in the Earth”. The prefix “Geo” is a Greek word, meaning…

Tidal Power: A Brand New Alternative Energy Source for Electricity Generation

Tidal power or tidal energy is an alternative energy source of hydropower from which you can generate electricity. As tidal energy doesn’t produce any…

Hydroelectric Energy: 10 Things You must Know About hydroelectricity

Hydroelectric Energy is almost all clean energy sources compared to all other renewable energy sources. Where Nuclear Power generates radioactive waste or wind energy generates…

Alternative Energy: A Detail Guide on Nuclear Power That You Must Read

There are some alternative energy sources available to cope with the increased demand for electricity. These alternative energy resources are…

Green Energy: Your Complete Guide on Wind Power to Generate Electricity

Green Energy means not the color of energy. Green energy is that source of renewable energy which you can use again and…